The innovation is the part of a new measurement that the Kalman filter could not predict. It drives the state update, and its statistics are the most important diagnostic tool for a running filter, because unlike the true estimation error they are available on real data.

Definition

The innovation is the difference between the measurement and the predicted measurement:

\[ \boldsymbol{\nu}(k) = \mathbf{y}(k) - \mathbf{C}(k)\mathbf{x}(k\vert k-1) \]

For a nonlinear measurement model, as in the EKF, the prediction is \( \mathbf{h}(\mathbf{x}(k\vert k-1)) \). Angular components, such as a bearing, must be wrapped to \( (-\pi, \pi] \).

Innovation covariance

Inserting \( \mathbf{y}(k) = \mathbf{C}(k)\mathbf{x}(k) + \mathbf{v}(k) \) shows that the innovation consists of the projected prediction error plus the measurement noise. Its covariance is therefore

\[ \mathbf{S}(k) = \mathbf{C}(k)\mathbf{P}(k\vert k-1)\mathbf{C}(k)^T + \mathbf{R}(k) . \]

\( \mathbf{S}(k) \) appears directly in the gain, \( \mathbf{K}(k) = \mathbf{P}(k\vert k-1)\mathbf{C}(k)^T\mathbf{S}(k)^{-1} \), and the update is \( \mathbf{x}(k) = \mathbf{x}(k\vert k-1) + \mathbf{K}(k)\boldsymbol{\nu}(k) \). The gain weighs the innovation by how much of its uncertainty comes from the state (\( \mathbf{C}\mathbf{P}\mathbf{C}^T \)) compared to the sensor (\( \mathbf{R} \)).

Properties of the innovation sequence

If the model is correct and the gain is optimal, the innovation sequence is

  1. zero-mean: \( E[\boldsymbol{\nu}(k)] = \mathbf{0} \),
  2. white: \( E[\boldsymbol{\nu}(k)\boldsymbol{\nu}(j)^T] = \mathbf{0} \) for \( k \neq j \),
  3. of covariance \( \mathbf{S}(k) \), and Gaussian if all noises are Gaussian.

Whiteness is the key property: an optimal filter extracts all predictable information from each measurement, so what remains cannot be correlated with past innovations. Any deviation is a symptom:

Symptom Likely cause
Non-zero mean sensor bias, missing input, model error
Correlated over time (colored) wrong \( \mathbf{Q} \) or \( \mathbf{R} \), unmodeled dynamics, colored measurement noise
Larger than \( \mathbf{S} \) filter overconfident: \( \mathbf{Q} \) or \( \mathbf{R} \) too small, linearization error
Smaller than \( \mathbf{S} \) filter too pessimistic: \( \mathbf{Q} \) or \( \mathbf{R} \) too large

Innovation vs. residual

The terms are often mixed up. The innovation (pre-fit residual) uses the predicted state, the residual (post-fit residual) uses the updated state:

\[ \boldsymbol{\epsilon}(k) = \mathbf{y}(k) - \mathbf{C}(k)\mathbf{x}(k) = \left(\mathbf{I} - \mathbf{C}(k)\mathbf{K}(k)\right)\boldsymbol{\nu}(k) = \mathbf{R}(k)\mathbf{S}(k)^{-1}\boldsymbol{\nu}(k) . \]

The residual is always smaller than the innovation because the update has already pulled the estimate toward the measurement. Consistency tests and gating therefore use the innovation.

What the innovation is used for

Consistency test (NIS). The normalized innovation squared \( \boldsymbol{\nu}^T\mathbf{S}^{-1}\boldsymbol{\nu} \) is chi-square distributed with \( n_y \) degrees of freedom. It is the standard check of a filter on real data, see NIS.

Gating and outlier rejection. A measurement is accepted only if its NIS is below a chi-square threshold, for example the 99 % quantile. In target tracking the same gate decides which measurements may be associated with a track.

Tuning. The autocorrelation of the innovation sequence can be used to estimate \( \mathbf{Q} \) and \( \mathbf{R} \), for example with the autocovariance least-squares method, see how to tune a Kalman filter. Adaptive filters scale \( \mathbf{Q} \) or \( \mathbf{R} \) online based on the innovation magnitude.

Model probabilities. The likelihood of a measurement under a model is the Gaussian density \( \mathcal{N}(\boldsymbol{\nu}; \mathbf{0}, \mathbf{S}) \). The Interacting Multiple Model filter uses it to weigh competing motion models.

Fault detection. Sudden jumps of the innovation indicate sensor faults or maneuvers. Trading applications use the normalized innovation as a z-score signal, see pairs trading.

References

[1] T. Kailath (1968). “An Innovations Approach to Least-Squares Estimation – Part I: Linear Filtering in Additive White Noise”. IEEE Transactions on Automatic Control, 13(6), 646–655.

[2] R. K. Mehra (1970). “On the Identification of Variances and Adaptive Kalman Filtering”. IEEE Transactions on Automatic Control, 15(2), 175–184.